4.4.5.2

HTTP

Loading and saving data via HTTP
The WBM allows you to store device data in an external file on your client PC or to load
such data from an external file from the PC to the devices. This means, for example, that
you can also load new firmware from a file located on your Admin PC. On this page, the
certificates required to establish a secure VPN connection can also be loaded.
Firmware
The firmware is signed and encrypted. This ensures that only firmware created by
Siemens can be downloaded to the device.
Configuration files
Note
Configuration files and Trial mode/Automatic Save
In "Automatic Save" mode, the data is saved automatically before the configuration files
(ConfigPack and Config) are transferred.
In "Trial" mode, although the changes are adopted, they are not saved in the
configuration files (ConfigPack and Config). Use the "Write Startup Config" button on the
"System > Configuration" WBM page to save changes in the configuration files.
CLI script file
You can download existing CLI configurations (RunningCLI).
Note
The downloadable CLI script is not intended to be uploaded again unchanged.
CLI commands for saving and loading files cannot be executed with the CLI script file
(Script).
Exchange of configuration data with STEP 7 Basic/Professional using a file
You use the two file types "RunningSINEMAConfig" and "SINEMAConfig" to exchange
configuration data between a device (WBM) and STEP 7 Basic/Professional via a file.
Requirements:
• Same article number
• Same firmware version
• Password
You assign the password in the WBM under "System > Load&Save > Passwords".
You can use the file types as follows:
• For offline diagnostics
You can save the faulty configuration of a device as "RunningSINEMAConfig" via the
WBM and import it in STEP 7 Basic/Professional. No connection to a real device is
SCALANCE SC-600 Web Based Management (WBM)
Configuration Manual, 10/2021, C79000-G8976-C475-03
Configuring with Web Based Management