Siemens SIMATIC NET SCALANCE SC-600 Configuration Manual page 261

Industrial ethernet security web based management (wbm)
Hide thumbs Also See for SIMATIC NET SCALANCE SC-600:
Table of Contents

Advertisement

• IP Assignment Method
Shows how the IPv4 address is assigned. The following values are possible:
– Static
– Dynamic (DHCP)
• Address Collision Detection Status
If new IPv4 addresses become active in the network, the "Address Collision
Detection" function checks whether this can result in address collisions. The allows
IPv4 addresses that would be assigned twice to be detected.
Note
The function does not run a cyclic check.
This column shows the current status of the function. The following values are
possible:
– Idle
– Starting
– Conflict
– Defending
– Active
– Not supported
– Disabled
SCALANCE SC-600 Web Based Management (WBM)
Configuration Manual, 10/2021, C79000-G8976-C475-03
The IPv4 address is static. You enter the settings in "IP Address" and "Subnet
Mask".
The device obtains a dynamic IPv4 address from a DHCPv4 server.
The interface is not enabled and does not have an IPv4 address.
This status indicates the start-up phase. In this phase, the device initially sends a
query as to whether the planned IPv4 address already exists. If the address is not
yet been assigned, the device sends the message that it is using this IP address as
of now.
The interface is not enabled. The interface is attempting to use an IPv4 address
that has already been assigned.
The interface uses a unique IPv4 address. Another interface is attempting to use
the same IPv4 address.
The interface uses a unique IPv4 address. There are no collisions.
The function for detection of address collisions is not supported.
The function for detection of address collisions is disabled.
Configuring with Web Based Management
4.6 "Layer 3" menu
261