Connections - Siemens SIMATIC NET SCALANCE SC-600 Configuration Manual

Industrial ethernet security web based management (wbm)
Hide thumbs Also See for SIMATIC NET SCALANCE SC-600:
Table of Contents

Advertisement

Configuring with Web Based Management
4.7 "Security" menu
4.7.7.2

Connections

On this WBM page, you configure the basic settings for the OpenVPN connection. You
specify the security settings on the WBM page "Authentication".
Description
• Connection name
Enter a unique name for the OpenVPN connection and click "Create" to create a new
connection.
The table contains the following columns:
• Select
Select the check box in the row to be deleted.
• Name
Shows the name of the OpenVPN connection.
• Operation
Specify how the connection is established.
– start
– start on DI
– Disabled
338
The device attempts to establish a VPN connection to the partner.
If the event "Digital In" occurs, the device attempts to establish a VPN connection
to the partner.
This is on condition that the event "Digital In" is forwarded to the VPN connection.
To do this in "System > Events> Configuration" activate "VPN Tunnel" for the
"Digital In" event.
The VPN connection is disabled.
SCALANCE SC-600 Web Based Management (WBM)
Configuration Manual, 10/2021, C79000-G8976-C475-03

Hide quick links:

Advertisement

Table of Contents
loading