Port Based Vlan - Siemens SIMATIC NET SCALANCE SC-600 Configuration Manual

Industrial ethernet security web based management (wbm)
Hide thumbs Also See for SIMATIC NET SCALANCE SC-600:
Table of Contents

Advertisement

Configuring with Web Based Management
4.5 "Layer 2" menu
4.5.2.2

Port Based VLAN

Processing received frames
On this WBM page, you specify the configuration of the port properties for receiving
frames.
Description
Table 1 has the following columns:
• All ports
Shows that the settings are valid for all ports of table 2.
• Priority / Port VID / Acceptable Frames / Ingress Filtering
In the drop-down list, select the setting for all ports. If "No Change" is selected, the
entries of the corresponding column in table 2 remain unchanged.
• Copy to Table
If you click the button, the setting is adopted for all ports of table 2.
Table 2 has the following columns:
• Port
Shows the available ports.
• Priority
Select the required priority assigned to untagged frames.
The CoS priority (Class of Service) used in the VLAN tag. If a frame is received
without a tag, it will be assigned this priority. This priority specifies how the frame is
further processed compared with other frames.
There are a total of eight priorities with values 0 to 7, where 7 represents the highest
priority (IEEE 802.1p Port Priority).