The User Specific BFP table has the following columns:
• User
The users configured locally on the device. The users that are not locally configured
on the device are summarized under the user name "UnknownUser".
• Failed Logins
The number of failed login attempts.
• Last Failed [s]
Time in seconds (s) since the last failed login attempt. To display the current value,
click the "Refresh" button.
• Blocked [s]
The time in seconds (s) until the blocking will be removed. To display the current
value, click the "Refresh" button.
When a blocked user attempts to log in before the timer expires, the timer restarts.
• Delete
Ends blocking for the user and resets the displays in the "Last Failed [s]" and
"Blocked [s]" boxes.
The IP Specific BFP table has the following columns:
• IP
The IP address of the device for the login attempt.
• Failed Logins
The current number of failed login attempts.
• Last Failed [s]
Time in seconds (s) since the last failed login attempt. To display the current value,
click the "Refresh" button.
• Blocked [s]
The time in seconds (s) until the blocking will be removed. To display the current
value, click the "Refresh" button.
When a blocked IP address attempts to log in before the timer expires, the timer
restarts.
• Delete
Ends blocking for the IP address and resets the displays in the "Last Failed [s]" and
"Blocked [s]" boxes.