Spanning Tree; General - Siemens SIMATIC NET SCALANCE SC-600 Configuration Manual

Industrial ethernet security web based management (wbm)
Hide thumbs Also See for SIMATIC NET SCALANCE SC-600:
Table of Contents

Advertisement

Configuring with Web Based Management
4.5 "Layer 2" menu
Restoring factory settings
If you have restored the factory defaults, ring redundancy is disabled and the default
ports are used as the ring ports. This can lead to circulating frames and failure of the
data traffic if other settings were used in a previous configuration.
4.5.5

Spanning Tree

4.5.5.1

General

General settings of the Spanning Tree protocol
On this page, you can enable Spanning Tree and select the protocol compatibility. By
default, the "Spanning Tree Protocol" (STP) is enabled.
Description of the displayed boxes
The page contains the following boxes:
• Spanning Tree
Enable or disable Spanning Tree.
Note
No operation of Spanning Tree with enabled ring redundancy
If ring redundancy is enabled under "Layer 2", Spanning Tree cannot be used.
• Protocol Compatibility
Select the protocol compatibility. The following settings are available:
– STP
– RSTP