• SNMP
You can configure setting in "System > SNMP > General".
– "-" (SNMP disabled)
– SNMPv1/v2c/v3
– SNMPv3
• Login Authentication
You configure the setting in "Security > AAA > General".
– Local
– RADIUS
– Local and RADIUS
– RADIUS and fallback local
• Password Policy
Shows which password policy is currently being used.
Local and external user accounts
You configure local user accounts and roles in "Security > Users".
When you create a local user account an external user account is generated
automatically.
Local user accounts involve users each with a password for logging in on the device.
SCALANCE SC-600 Web Based Management (WBM)
Configuration Manual, 10/2021, C79000-G8976-C475-03
Access to device parameters via SNMP is not possible.
Access to device parameters is possible with SNMP versions 1, 2c or 3.
Access to device parameters is possible only with SNMP version 3.
The authentication must be made locally on the device.
The authentication must be handled via a RADIUS server.
The authentication is possible both with the users that exist on the device (user
name and password) and via a RADIUS server.
The user is first searched for in the local database. If the user does not exist there,
a RADIUS query is sent.
The authentication must be handled via a RADIUS server.
A local authentication is performed only when the RADIUS server cannot be
reached in the network.