Agent Syslog Configuration - Siemens SCALANCE X-300 Configuration Manual

Industrial ethernet switches
Hide thumbs Also See for SCALANCE X-300:
Table of Contents

Advertisement

Configuration using Web Based Management and Command Line Interface
4.4 The Agent menu
4.4.8

Agent Syslog Configuration

Application
Syslog according to RFC 3164 is used for transferring short, unencrypted text messages
over UDP in the IP network. This requires a standard Syslog server.
Log book entries can only be sent when
● The Syslog function is enabled on the IE Switch (see section "Agent Configuration")
● The Syslog function is enabled for the relevant event (see 
 A gent Event Configuration
menu item)
● There is a Syslog server in your network that receives the log entries from the IE switch.
(Since this is a UDP connection, there is no acknowledgment to the IE Switch)
● The IP address of the Syslog server is entered on the IE switch.
Figure 4-39
Syslog Server IP Address
Here, you enter the IP address of the Syslog server on which the log entries will be stored.
Syslog Server Port
The UDP port via which the log entries will be stored on the server.
Syntax of the Command Line Interface
Table 4- 29
Command
info
server [<ip>[:port]]
114
Agent Syslog Configuration
Agent Syslog Configuration - CLI\AGENT\SYSLOG>
Description
Shows the current Syslog con-
figuration.
Specifies the IP address and the
port number of the Syslog serv-
er.
Comment
-
Administrator only.
Default value: 0.0.0.0:514
Configuration Manual, 10/2014, C79000-G8976-C187-22