Siemens SIMATIC NET SCALANCE SC-600 Configuration Manual page 351

Industrial ethernet security web based management (wbm)
Hide thumbs Also See for SIMATIC NET SCALANCE SC-600:
Table of Contents

Advertisement

Requirement
• The device has an IP address.
• The user is logged in with administrator rights.
Firmware update via HTTP
1. Click "System > Load&Save" in the navigation area. Click the "HTTP" tab.
2. Click the "Upload" button next to "Firmware".
3. Go to the storage location of the firmware file.
4. Click the "Open" button in the dialog. The file is uploaded.
Firmware update via TFTP
1. Click "System > Load&Save" in the navigation area. Click the "TFTP" tab.
2. Enter the IP address of the TFTP server in the "TFTP Server Address" input box.
3. Enter the server port in the "TFTP Server Port" input box.
4. Select the action "Load file" in the "Firmware" table row. Make sure that the file name
is correct.
5. Click the "Set Values" button. The file is uploaded.
Firmware update via SFTP
1. Click "System > Load&Save" in the navigation area. Click the "SFTP" tab.
2. Enter the IP address of the SFTP server in the "SFTP Server Address" input box.
3. Enter the server port in the "SFTP Server Port" input box.
4. Select the action "Load file" in the "Firmware" table row. Make sure that the file name
is correct.
5. Click the "Set Values" button. The file is uploaded.
Result
When the firmware is successfully loaded, a dialog is displayed. Confirm the dialog with
"OK". The device is restarted.
In "Information > Versions" there is the additional entry "Firmware_Running".
Firmware_Running shows the version of the current firmware. For "Firmware", the
firmware version stored after loading the firmware is displayed.
SCALANCE SC-600 Web Based Management (WBM)
Configuration Manual, 10/2021, C79000-G8976-C475-03
Upkeep and maintenance
5.2 Firmware update using WBM not possible
351