• Device Type
Shows the device type within the product line that used the C-PLUG or KEY-PLUG
previously.
• Configuration Revision
The version of the configuration structure. This information relates to the
configuration options supported by the device and has nothing to do with the
concrete hardware configuration. This revision information does not therefore change
if you add or remove additional components (modules or extenders), it can, however,
change if you update the firmware.
• File System
Displays the type of file system on the PLUG.
• File System Size
Displays the maximum storage capacity of the file system on the PLUG.
• File System Usage
Displays the memory utilization of the file system of the PLUG.
• Firmware on PLUG
When the function is enabled (default), the firmware will be stored on the PLUG. This
means that automatic firmware updates/downgrades can be made with the PLUG.
The "Info" box shows whether or not the firmware is stored on the PLUG.
Note
C-PLUG 256 MB V2.2 and higher
As of firmware version 2.2, you can only save the firmware on a C-PLUG with 256 MB.
• Info String
Shows additional information about the device that used the PLUG previously, for
example, article number, type designation, and the versions of the hardware and
software. The displayed software version corresponds to the version in which the
configuration was last changed. With the "NOT ACCEPTED" status, further
information on the cause of the problem is displayed.
If a PLUG was configured as a PRESET PLUG this is shown here as additional
information in the first row. For more detailed information on creating and using a
PRESET PLUG refer to the section "Maintenance (Page 347)".
• Modify PLUG
Select the setting from the drop-down list. You have the following options for
changing the configuration on the C-PLUG or KEY-PLUG:
– Write Current Configuration to the PLUG
– Erase PLUG to factory default
SCALANCE SC-600 Web Based Management (WBM)
Configuration Manual, 10/2021, C79000-G8976-C475-03
This option is available only if the status of the PLUG is "NOT ACCEPTED" or
"FACTORY".
The configuration in the internal flash memory of the device is copied to the PLUG.
Deletes all data from the PLUG and triggers low-level formatting.
Configuring with Web Based Management
4.4 "System" menu
213