Smtp Client; General - Siemens SIMATIC NET SCALANCE SC-600 Configuration Manual

Industrial ethernet security web based management (wbm)
Hide thumbs Also See for SIMATIC NET SCALANCE SC-600:
Table of Contents

Advertisement

Configuring with Web Based Management
4.4 "System" menu
Description
The table has the following columns:
Select the client type for which you want to make settings:
– Log Table
– Syslog
• Severity
Select the required Severity. The following settings are possible:
– Info
– Warning
– Critical
4.4.7

SMTP client

4.4.7.1

General

Network monitoring with e-mails
If events occur, the device can automatically send an e-mail, e.g. to the service
technician. The e-mail contains the identification of the sending device, a description of
the cause in plain text, and a time stamp. This allows centralized network monitoring to
be set up for networks with few nodes based on an e-mail system.
152
Client Type
Entry of system events in the log table.
Entry of system events in the Syslog file.
The messages of all Severity are sent or logged.
The message of this Severity and the "Critical" level are sent or logged.
Only the messages of this Severity are sent or logged.
SCALANCE SC-600 Web Based Management (WBM)
Configuration Manual, 10/2021, C79000-G8976-C475-03