Configuring with Web Based Management
4.7 "Security" menu
• Source Port (Range)
Enter the source port. The rule applies specifically to the specified port.
– If the rule is intended to apply to a port range, enter the range with start port "-"
– If the rule is intended to apply to all ports, enter "*".
• Destination Port (Range)
Enter the destination port. The rule applies specifically to the specified port.
– If the rule is intended to apply to a port range, enter the range with start port "-"
– If the rule is intended to apply to all ports, enter "*".
4.7.5.5

ICMP services

On this WBM page, you define ICMP services. Using the ICMP service definitions, you
can define firewall rules for specific services. You select a name and assign the service
parameters to it. When you configure the IP rules, you simply use this name.
Description
The page contains the following:
• Service Name
Enter a name for the ICMP service. The name must be unique.
The table contains the following columns:
• Select
Select the check box in the row to be deleted.
• Service Name
Shows the name of the ICMP service.