Plug; Configuration - Siemens SIMATIC NET SCALANCE SC-600 Configuration Manual

Industrial ethernet security web based management (wbm)
Hide thumbs Also See for SIMATIC NET SCALANCE SC-600:
Table of Contents

Advertisement

4.4.16

PLUG

4.4.16.1

Configuration

NOTICE
Do not remove or insert a C-PLUG / KEY-PLUG during operation!
A PLUG may only be removed or inserted when the device is turned off.
The device checks whether a PLUG is present at one second intervals. If it is detected
that the PLUG was removed, there is a restart. If a valid KEY-PLUG was inserted in the
device, the device changes to a defined error state following the restart. With
SCALANCE M, the available wireless interfaces are deactivated in this case.
If the device was configured at some time with a PLUG, the device can no longer be
used without this PLUG. To be able to use the device again, reset the device to the
factory settings.
Information about the configuration of the KEY-PLUG
This page provides detailed information about the configuration stored on the C-PLUG. It
is also possible to reset the PLUG to "factory defaults" or to load it with new contents.
Note
Incompatibility with older firmware versions with PLUG inserted
During the installation of an older firmware version, the configuration data can be lost. In
this case, reset the device to the factory settings after the firmware has been installed.
In this situation, when a PLUG is inserted in the device, following the restart, this has the
status "NOT ACCEPTED" because the PLUG still has the configuration data of the
previous more up-to-date firmware. This allows you to return to the previous, more up-
to-date firmware without any loss of configuration data.
If the original configuration on the PLUG is no longer required, the PLUG can be deleted
or rewritten manually using "System > PLUG".
Note
The action is only executed after you click the "Set Values" button.
The action cannot be undone.
If you decide against executing the function after making your selection, click the
"Refresh" button. As a result the data of this page is read from the device again and the
selection is canceled.
SCALANCE SC-600 Web Based Management (WBM)
Configuration Manual, 10/2021, C79000-G8976-C475-03
Configuring with Web Based Management
4.4 "System" menu
211

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents