Siemens SIMATIC NET SCALANCE SC-600 Configuration Manual page 311

Industrial ethernet security web based management (wbm)
Hide thumbs Also See for SIMATIC NET SCALANCE SC-600:
Table of Contents

Advertisement

"Rule Set Assignment" area
• Type
Specify which rule set will be assigned to whom. The display of the following table
depends on the selection for "Type".
– Account
– Digital input
– Radius Role
– RADIUS User
– Time triggered
The "User Account" table contains the following columns:
• Account
Only users with the remote access "only" or "additional" are displayed.
• Role
Shows the role of the user.
• Rule set
Define the rule set that is valid for this user.
• Combined with
Combines the user login with an event, e.g. the "Digital Input" event. To log in to the
WBM page for the dynamic firewall, voltage must be present at the digital input and
user login must be successful.
• Remaining Time
When this user is logged on, the remaining time for access is displayed.
• Force Deactivate
A user with administrator rights can log off the active user with this button.
The "Digital Input" table contains the following columns:
• Digital In
The available digital inputs.
• Rule set
Define the rule set that is controlled via the digital input.
SCALANCE SC-600 Web Based Management (WBM)
Configuration Manual, 10/2021, C79000-G8976-C475-03
The rule set is activated through a local user account.
The rule set is executed by controlling the digital input. The prerequisite for this is
that the entry "Digital Input" is activated for the "Firewall" event under "System >
Events > Configuration".
The rule set is activated through a RADIUS role.
The rule set is activated through a RADIUS user.
Enforcement of the rule set is time-triggered.
Configuring with Web Based Management
4.7 "Security" menu
311