Siemens SIMATIC NET SCALANCE SC-600 Configuration Manual page 120

Industrial ethernet security web based management (wbm)
Hide thumbs Also See for SIMATIC NET SCALANCE SC-600:
Table of Contents

Advertisement

Configuring with Web Based Management
4.4 "System" menu
• SSH key exchange algorithm level
Configure the level of SSH key exchange algorithm for SSH access to the CLI.
High (default)
– Curve25519-sha256
– Curve25519-sha256@libssh.org
– Ecdh-sha2-nistp256
– Ecdh-sha2-nistp384
– Ecdh-sha2-nistp521
– Diffie-hellman-group16-sha512
– Diffie-hellman-group18-sha512
Low
– Curve25519-sha256
– Curve25519-sha256@libssh.org
– Ecdh-sha2-nistp256
– Ecdh-sha2-nistp384
– Ecdh-sha2-nistp521
– Diffie-hellman-group16-sha512
– Diffie-hellman-group18-sha512
– Diffie-hellman-group14-sha256
– Diffie-hellman-group14-sha1
• HTTP Server
Enable or disable HTTP access to the WBM.
• HTTP Port
Specify the port for HTTP access to the WBM.
• HTTPS Server
Enable or disable HTTP access to the WBM.
• HTTPS Port
Specify the port for HTTPS access to the WBM.
• HTTP Services
Specify how the WBM is accessed:
– HTTPS
– Redirect HTTP to HTTPS
120
Access to the WBM is only possible with HTTPS.
Access via HTTP is automatically diverted to HTTPS.
SCALANCE SC-600 Web Based Management (WBM)
Configuration Manual, 10/2021, C79000-G8976-C475-03