Configuring with Web Based Management
4.4 "System" menu
Requirement:
To adapt network parameters, DCP requires write access to the device. If access is
write-protected, the network parameters cannot be configured.
On devices, you configure access under "System > Configuration".
Description
The page contains the following boxes:
• Timeout[s]
Specify the time for flashing of own LEDs. When the time elapses, flashing stops.
• Interface
Select the required interface.
• Browse
Starts the search for devices reachable via the selected interface.
On completion of the search the reachable devices are listed in the table. The table is
limited to 100 entries.
The table has the following columns:
• Port
Shows the port via which the device can be reached.
• MAC Address
Shows the MAC address of the device.
• Device Type
Shows the product line or product group to which the device belongs.
• Device Name
Adapt the PROFINET device name if necessary. The device name must be DNS-
compliant.
If the device name is not used, the box is empty.
• IP Address
If necessary, adapt the IPv4 address of the device.
The IPv4 address should be unique within your network and should match the
network. The IPv4 address 0.0.0.0 means that no IPv4 address has yet been set.
• Subnet mask
If necessary, adapt the subnet mask of the device.
• Gateway Address
Adapt the IPv4 address of the gateway if necessary.
218
SCALANCE SC-600 Web Based Management (WBM)
Configuration Manual, 10/2021, C79000-G8976-C475-03