Siemens SIMATIC NET SCALANCE SC-600 Configuration Manual page 228

Industrial ethernet security web based management (wbm)
Hide thumbs Also See for SIMATIC NET SCALANCE SC-600:
Table of Contents

Advertisement

Configuring with Web Based Management
4.4 "System" menu
"Server settings" area
• SINEMA RC Address
Enter the IP address or the FQDN (Fully Qualified Domain Name) of the SINEMA RC
Server.
• SINEMA RC Port
Enter the port via which the SINEMA RC Server can be reached.
"Server Verification" area
• Verification Type
– Fingerprint: The identity of the server is verified based on the fingerprint.
– CA Certificate: The identity of the server is verified based on the CA certificate.
• Fingerprint
Only necessary with the setting "Fingerprint". Enter the fingerprint of the device. The
fingerprint is assigned during commissioning of the SINEMA RC Server. Based on the
fingerprint, the device checks whether the correct SINEMA RC Server is involved. You
will find further information on this in the Operating Instructions of the SINEMA RC
Server.
• CA Certificate
Only necessary with the setting "CA Certificate". Select the CA certificate of the
server used to sign the server certificate. Only loaded CA certificates can be selected.
"Device Credentials" area
• Device ID
Enter the device ID. The device ID is assigned when configuring the device on the
SINEMA RC Server. You will find further information on this in the Operating
Instructions of the SINEMA RC Server.
• Device Password
Enter the password with which the device logs on to the SINEMA RC Server. The
password is assigned when configuring the device on the SINEMA RC Server. You will
find further information on this in the Operating Instructions of the SINEMA RC
Server.
• Device Password Confirmation
Repeat the password.
228
SCALANCE SC-600 Web Based Management (WBM)
Configuration Manual, 10/2021, C79000-G8976-C475-03