Siemens SIMATIC NET SCALANCE SC-600 Configuration Manual page 207

Industrial ethernet security web based management (wbm)
Hide thumbs Also See for SIMATIC NET SCALANCE SC-600:
Table of Contents

Advertisement

• Blocked by
• Shows why the port is in the "blocked" status:
– -
– Admin down
– Link down
– Power down
Changing the port configuration
Click the appropriate box to change the configuration.
Note
Optical ports only work with the full duplex mode and at maximum transmission rate. As
a result, the following settings cannot be made for optical ports:
• Automatic configuration
• Transmission speed
• Transmission mode
Note
With various automatic functions, the device prevents or reduces the effect on other
ports and priority classes (Class of Service) if a port is overloaded. This can mean that
frames are discarded even when flow control is enabled.
Port overload occurs when the device receives more frames than it can send, for
example as the result of different transmission speeds.
Configuration procedure
1. Change the settings according to your configuration.
2. Click the "Set Values" button.
SCALANCE SC-600 Web Based Management (WBM)
Configuration Manual, 10/2021, C79000-G8976-C475-03
The port is not blocked.
The status "disabled" is configured for the port, see "System > Ports >
Configuration".
The status "enabled" is configured for the port but there is no connection, see
"System > Ports > Configuration".
The status "Link down" is configured for the port, see "System > Ports >
Configuration".
Configuring with Web Based Management
4.4 "System" menu
207