Static Routes - Siemens SIMATIC NET SCALANCE SC-600 Configuration Manual

Industrial ethernet security web based management (wbm)
Hide thumbs Also See for SIMATIC NET SCALANCE SC-600:
Table of Contents

Advertisement

Configuring with Web Based Management
4.6 "Layer 3" menu
• Alias IP
When enabled, Alias IP addresses are created for the implemented address range.
Enabled automatically when a /32 address is entered.
– Source: For all IP addresses entered in the "Translated Source IP Subnet" field,
– Destination: For all IP addresses entered in the "Destination IP Subnet" field, Alias
Note
Enabling in combination with network or address range
When you enable the option in combination with a network or address range, the
Alias IP addresses are reserved for the entire network or address range. This can lead
to network problems.
• VRRP Interface / VRID
Selection is only possible when the "Alias IP" option is enabled.
Shows all configured routers of the type "VRRPv3" that are created in the "Layer 3 >
VRRPv3 > Router" menu.
When you select a VRRP3 router, the Alias IP address associated with this NETMAP
rule is only active when the VRRP3 router has the router status "Master".
• Comment
If needed, enter a comment.
4.6.3

Static routes

On this page, you specify the routes via which data exchange can take place between
the various subnets. Dynamic routing protocols are not supported, for example RIP,
OSPF.
272
Alias IP addresses are created at the "Destination Interface".
IP addresses are created at the "Source Interface".
SCALANCE SC-600 Web Based Management (WBM)