The "System Save & Load Http" Wbm Menu - Siemens SCALANCE X-100 Commissioning Manual

Scalance industrial ethernet product line
Hide thumbs Also See for SCALANCE X-100:
Table of Contents

Advertisement

Diagnostics over Industrial Ethernet
6.2 Web Based Management (WBM)
• System contact
There is no automatic restart, the parameters take effect immediately. In the user mode, this
button is invisible.
Restore Factory Defaults and Restart Button
Click this button to restore the factory defaults for the configuration. The protected defaults
are also reset. In the user mode, this button is invisible.
6.2.4.4
The "System Save & Load HTTP" WBM Menu
System Save & Load HTTP
The WBM allows you to store configuration information in an external file on your client PC
or to load such data from an external file from the PC to the SCALANCE X-200.
You can also load new firmware from a file located on your client PC. You can make the
entries required for this on the page of the System Save & Load HTTP menu.
Figure 6-9
Configuration File Text Box
Name and possibly also folder path of the configuration file (maximum 32 characters) that
you want to load on the SCALANCE X-200 or where you want to store the current
configuration information
Firmware File Text Box
Name and possibly also folder path of the file (maximum 32 characters) from which you want
to load the new firmware.
6-14
"System Save & Load via HTTP" Dialog
Industrial Ethernet SCALANCE X-100 and SCALANCE X-200 Product Line
Commissioning Manual, 1,

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Scalance x-200

Table of Contents