6-5-4. Capstan FG Duty Automatic Adjustment
For explanation of SV04: Capstan FG Duty Adjust, refer to Section 6-2.
(1) Enter SV04: Capstan FG Duty Adjust.
(2) When the adjustment succeeds, message "Adjust
Complete" is displayed.
(3) If necessary, enter SV0C: SV NV-RAM Save
(Refer to Section 6-5-12).
n
It takes time to terminate the command when an SV0C
command is executed. To perform other servo adjustments
continuously, execute the SV0C command after all the
servo adjustments are completed.
6-5-5. S Reel Motor Offset/Friction Automatic Adjustment
For explanation of SV05: S Reel offset/friction Adjust, refer to Section 6-2.
(1) Enter SV05: S Reel offset/friction Adjust.
(2) When the adjustment succeeds, message "Adjust
Complete" is displayed.
(3) If necessary, enter SV0C: SV NV-RAM Save
(Refer to Section 6-5-12).
n
It takes time to terminate the command when an SV0C
command is executed. To perform other servo adjustments
continuously, execute the SV0C command after all the
servo adjustments are completed.
GY-2120WD/WS
------>SV04
Servo Adjust [Auto Adjust]
Capstan FG Duty Adjust
Adjust Complete
------>_
------>SV05
Servo Adjust [Auto Adjust]
S Reel offset/fricton Adjust
Adjust Complete
------>_
6-5. Servo System Alignment
6-195