2-1. Cleaning

2-1-4. Stationary Heads Cleaning

c
Be careful not to damage the head surface when cleaning the stationary heads.
Tools
. Cleaning cloth: 3-184-527-01
. Cleaning fluid: 9-919-573-01
Procedures
1. Clean the tape running surfaces of the CTL/TC head and Full erase head in the
vertical direction with a cleaning cloth moistened with a cleaning fluid.
c
An error may occur in the recording or playback when magnetic powder
attaches to the head gap portion of the CTL/TC head and Full erase head.
Remove the magnetic powder completely during cleaning.
2. After cleaning, wipe it with a dry cleaning cloth two or three times.