5 Log parameters
Log Parameter
1'st Vol [XXXXXX-YYYYYY]
ABN [XXXXXXXX]
Address [XXXXXXXX]
Bank [XXXXX]
Block [XXXX]
Bod [XXXXXX]
Bop [XXXXXX]
BS [XXXXXX]
C2ID [XXXXXX]
Cause1 [XX]
Cause2 [XX]
Cmnd [XXXXXXXX]
Command [X]
Derr [XXXXXXXX]
DIT#1 [XXXXXX]
EOD [XXXXXX]
Eop [XXXXXX]
FActMode [XXXXXXXX]
FILE [XXXXXX]
fLoad [XXXXXXXX]
HOST [X]
ID [XXXXXXX]
Inhi [XXXX]
lEot [XXXXXX]
len [XXXXXXXX]
Length [XXXXXXXX]
Leot [XXXXXX]
NumRecv [XXXXX]
Mode [XXXX]
OWC [XXXXXXXX]
OWN [X]
Rsv [XXXXXXXX]
Scsi [XX]
ScsiCmd [XX]
sync : X
Tape [XXXXXXXX]
TAR (XXXXXXXX)[Y]
Tbl [XXXXXXX]
TopID [XXXXXX]
VolCnt [XXX]
VolNo. [XXX]
wide : X
GY-2120WD/WS
Contents
First volume range (Unit is ID)
Block number managed by DTF displayed in HEX
ID number in the bank with error
Bank number with error
Block size value
Top of data of mounted volume. Unit is ID.
Top of the mounted volume. Unit is ID.
Number of bad spots in the volume
Position at which the error occurred. Unit is ID.
Internal I/O status of GY-2120 or error number of GY-2120 *
Internal I/O status in GY-2120
When * "Drive Power Error!!, "Drive System Error!!"...Always 0
Error code from the SYS side CPU
Maintenance mode command
SYS side error code
Top position of first volume. Unit is ID.
EOD position in the volume. Unit is ID.
Last position of mounted volume. Unit is ID.
GY-2120 internal mode
Number of filemarks or set marks in the volume
Internal load state of GY-2120
Host SCSI ID
ID number in the bank read
Recording-prohibited mode value
Last position of the tape. Unit is ID.
Block data length
Memory address in the ID
EOT position of the tape. Unit is ID.
Number of faults detected
Buffer mode value
Overwrite count for the volume
GY-2120 SCSI ID
(Always 0)
SCSI command during error or execution
SCSI command executed
Sync mode
Unique number of the tape
Targetted model name and SCSI ID
Block table managed by DTF. Displayed in HEX.
Position inside the bank with the error. Unit is ID.
Number of volumes in the tape
Targetted volume number
Wide mode
6-2. Command Description
6-35