Main Machine Installation
16. Remove the charge roller unit and place it on a clean, flat surface with the roller facing up ( x2).
• Make sure that the surface is flat and level.
17. Remove the filament tapes [A] and retainers [B] from both ends of the charge roller unit.
18. Reattach the charger roller unit and PCDU, and then attach the face plate.