4-3: Amp1 Eg - Korg NAUTILUS Series Parameter Manual

Hide thumbs Also See for NAUTILUS Series:
Table of Contents

Advertisement

4–3: Amp1 EG
4–3a
4–3b
4–3c
4–3d
These parameters let you create time-varying changes in the
volume of oscillator 1.
4–3a: EG Reset
AMS (EG Reset)
This selects an AMS source to reset the EG to the start point.
For instance, you can use a tempo-synced LFO to trigger the
EG in a repeating rhythm. This reset is in addition to the
initial note-on, which always causes the EG to start.
Note: Once the Amp EG is in its Release segment, it cannot
be reset. (Otherwise, the sound might keep playing forever!)
For a list of AMS sources, see "Alternate Modulation Source
(AMS) List" on page 901.
Threshold
This sets the AMS level which will trigger the EG reset.
Among other things, you can use this to adjust the exact
point in an LFO's phase at which the EG will be reset,
effectively controlling its "groove" against other rhythmic
effects.
When the threshold is positive, the EG triggers when
passing through the threshold moving upwards. When the
threshold is negative, the EG triggers when passing through
the threshold moving downwards.
Note: With some LFO shapes, and with faster LFO speeds,
the LFO may not always reach the extreme values of +99 or
-99. In this case, setting the Threshold to these values may
cause inconsistent behavior, or may mean that the EG
doesn't reset at all. If this happens, reduce the Threshold
until the EG triggers consistently.
[List of AMS Sources]
[–99...+99]
PROGRAM > Amp/EQ 4–3: Amp1 EG
4–3b: Envelope
These parameters specify how the amp 1 EG will change
over time.
Amp EG
Start
Attack
Break
Level
Level
Level
Volume
Time
Attack
Decay
Time
Time
Note-on or reset
Level
Start
This sets the initial volume level at note-on.
Attack
This sets the level at the end of the Attack time.
Break
Break, short for Break Point, sets the level at the end of the
Decay time.
Sustain
This sets the level at the end of the Slope time. Once it
reaches the Sustain level, the EG will stay there until note-
off (unless it is reset via AMS).
4–3PMC
Sustain
Level
Slope
Release
Time
Time
Note-off
[00...99]
[00...99]
[00...99]
[00...99]
79