Settings on the Fibre Channel Card (8Gbps FC Card)
CHAPTER 2
Card (8Gbps FC Card)
This chapter describes the settings to be made on the 8Gbps FC Card in the PRIMEQUEST 2000 series server. With the
resultant settings, the system starts from an LUN of the SAN storage unit in the FC SAN boot environment.
2.1
Procedure for Setting UEFI Driver Version 4.13a6 or Later on
the 8Gbps FC Card
This section describes the procedure for setting UEFI driver version 4.13a6 or later.
To have the system start from a LUN of the SAN storage unit in the SAN boot environment, the operation described below
is required for all of the HBAs to be used for starting the system.
Executing this operation registers in the HBA the SAN storage unit LUN from which the system is to be started. This
section uses examples of screen displays resulting from the use of UEFI driver versions 4.13a6. All screenshots appearing
below are display examples whose contents vary depending on the system configuration, etc.
Notes
To add sadump as dump device of SAN, setting LUN by selecting [Add Boot Device] on the UEFI driver utility is
required.
If the UEFI boot menu has the setup menu, select the setup menu and proceed to the work described in 2.1.3 Starting
the HBA setup utility.
When the setting is adding changed by the above-mentioned, the partition rebooting is necessary.
please execute the action after rebooting a pertinent partition.
Please push either of key (space key) while the FUJITSU logo is displayed. 'Enter' is excluded.
When the above-mentioned is not done, the dump device is not added.