256
Installing and Wiring Telephones
Hard-Wire Bridging
Analog type hard-wire bridging is not allowed for any DCP endpoints. Hard-wire bridging
provides no way of combining the digital output of two bridged DCP sets. Also, a bridged
endpoint causes degradation of the DCP signal.
!
CAUTION:
Bridging or paralleling these endpoints can cause electrical damage to the consoles or
cause the circuit pack to remove power from the consoles.
Dual Wiring of 2-Wire and 4-Wire Endpoints
Do not simultaneously wire a 2-wire and 4-wire endpoint to the same equipment location in an
MDF. The Avaya configurations use separate circuit packs to interface 2- and 4-wire endpoints.
Install the Attendant Console
1
Install the attendant console and connect the modular cord to the information outlet.
Install labels per the attendant console form and the Display Module form assignments.
2
3
Install a digital line circuit pack in the assigned carrier slot (if an additional circuit pack
is required).
4
Administer the forms listed in "Attendant Console" in Administrator's Guide for Avaya
MultiVantage Software.
302D Console
Install the 26B1 Selector Console
Connect the supplied 3-foot (1 meter) D8AC cable to the modular jack on the bottom of
1
the 26B1 Selector Console.
October 2002