Avaya S8700 Installing Manual page 180

With media gateways
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

180
Patch Cord/Jumper Installation and Administration
To connect the trunk pairs to the purple field:
1
Connect B25A cables between the network interface and the sneak fuse panels. See
''3-Pair Modularity for Trunk Pairs for 1-Pair Trunks'' on page
2
Connect A25D/B25A cables from the sneak fuse panels to the 110-type terminal
block-type connecting block connectors in the green field.
3
Connect 1-pair patch cords/jumper wires from each 110-type terminal block row in the
green field to the 110-type terminal block rows in the purple field for 1-pair Central
Office (CO) trunks or in
page 181
3-Pair Modularity for Trunk Pairs for 1-Pair Trunks
Figure notes
1
2
''3-Pair Modularity for Trunk Pairs for 3-Pair Tie Trunks'' on
for 3-pair tie trunks.
1 2 3 4 5 6 7 8
1 4 7 10 13 16 19 22
Green Field
1-Pair Jumpers
9 10 11 12 13 14 15 16
1 4 7 10 13 16 19 22
Pairs
3
4
Purple Field
October 2002
180.
17 18 19 20 21 22 23 24
1 4 7 10 13 16 19 22
r758425b MMR 031496

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mcc1Scc1

Table of Contents