Connect An Analog Station Or 2-Wire Digital Station - Avaya S8700 Installing Manual

With media gateways
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

400B2 Adapter Connecting to a Modular Plug
Figure notes
Flush-Mounted Information Outlet
1
2
Surface-Mounted Information Outlet
3
To Individual Power Unit
Connect an Analog Station or 2-Wire Digital
Station
This example is typical of the 2-wire digital stations (2420, 64xx, 302D), 2-wire analog stations
(2500), analog Central Office (CO) trunks, Direct Inward Dial (DID) trunks, and external
alarms. See
''2500-Type Analog Telephone Wiring'' on page
Choose a peripheral to connect (such as a 2-wire digital station).
1
Choose the port circuit pack to use and its carrier and slot number (from
2
Pack and Telephone Pin Designations'' on page
Line, Cabinet 1, Carrier C, Slot 1.
3
Choose a port circuit on the port circuit pack, for example port 3.
Install cross-connect jumpers to connect the pins from the 2-wire digital station to the
4
appropriate pins on the port circuit pack.
Administer using Administrator's Guide for Avaya MultiVantage Software.
5
400B2 Adapter
4
5
To Telephone
6
Destination Service Access Point
(DSAP) Power Cord
244). For example: TN2183 Analog
October 2002
Installing and Wiring Telephones
r749428 KLC 060396
244.
''Port Circuit
243