Connect Power Distribution Unit External Alarm Wires - Avaya S8700 Installing Manual

With media gateways
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

258
Installing and Wiring Telephones
Emergency Transfer and Auxiliary Power
Color
Black-Green
Green-Black
Black-Slate
Slate-Black
Connect Power Distribution Unit External Alarm
Wires
The external alarm plug should already be connected to the J58890CH-1 Power Distribution
Unit. The pinout for the connector is shown in
259.
NOTE:
RS232 alarms (RXD, DTR, DSR, TXD, RS-232 GRD, and RTS) are not supported on the
BU3200A Battery Interface Unit.
Choose an alarm to connect (such as Battery Interface Failure).
1
2
Choose the port circuit pack to use and its carrier and slot number (from
Pack and Telephone Pin Designations'' on page
Line, cabinet 1, carrier C, slot 1.
Choose a port circuit on the port circuit pack, for example port 3.
3
Install cross-connect jumpers to connect the named pins from the alarm wires to the
4
appropriate pins on the port circuit pack.
NOTE:
It is recommended that the RFA, ACF, and BIF alarm leads be connected to the major
alarm device and the BOD alarm leads be connected to the minor alarm device.
5
Connect the major and minor alarm devices to the appropriate cross-connect pins on the
MDF.
6
Administer the alarms using the Administrator's Guide for Avaya MultiVantage Software.
AUX Connector
XFER48 (Emergency Transfer) (Pin 36)
Ground (Pin 11)
ACC48A (Adjunct -48 VDC) (Pin 19)
Ground (Pin 44)
October 2002
''External Alarm Connector Pinout'' on page
244). For example, TN2183 Analog