3-Pair and 4-Pair Modularity
Figure notes
1
Port Circuit Pack
Media Gateway Connector Pins
2
(3-Pair Modularity)
3
Main Distribution Frame (MDF) Pins
(3-Pair Modularity)
4
Input to Information Outlet (4-Pair
Modularity)

Adjunct Power Connection Locations

''Example Adjunct Power Connections'' on page 254
adjunct power. Adjunct power for station equipment may be supplied from the equipment room,
satellite location, or the work location.
For this figure, the following example is used:
1
If 25 telephones are connected to the media gateway and all 25 telephones need adjunct
power, install a bulk power supply in the equipment room.
If only ten of the telephones need adjunct power, install a bulk power supply at the
2
satellite location.
If only one telephone needs adjunct power, install the individual power supply at the
3
work location.
5
Adjunct Power
Output From Information Outlet
6
(4-Pair Modularity)
7
Voice or Data Terminal Pins
shows typical connection locations for
October 2002
Installing and Wiring Telephones
253