12.Compulsory Valve Operation
Check Mode
A: OPERATION
1) Prepare the Subaru Select Monitor kit. <Ref. to
EN(H4DOTC)(diag)-7,
General Description.>
2) Connect the diagnosis cable to Subaru Select
Monitor.
3) Insert the cartridge to Subaru Select Monitor.
<Ref. to EN(H4DOTC)(diag)-7, PREPARATION
TOOL, General Description.>
4) Connect the test mode connector (A) located at
the lower portion of glove box.
(A)
Compulsory Valve Operation Check Mode
PREPARATION
TOOL,
EN-00038
EN-00039
EN-01983
EN(H4DOTC)(diag)-31
5) Connect the Subaru Select Monitor to data link
connector located in the lower portion of the instru-
ment panel (on the driver's side).
CAUTION:
Do not connect the scan tools except for Suba-
ru Select Monitor.
6) Turn ignition switch to ON (engine OFF) and turn
Subaru Select Monitor switch to ON.
(A) Power switch
7) On the «Main Menu» display screen, select the
{Each System Check} and press the [YES] key.
8) On the «System Selection Menu» display
screen, select the {Engine} and press the [YES]
key.
9) Press the [YES] key after the information of en-
gine type was displayed.
10) On the «Engine Diagnosis» display screen, se-
lect the {System Operation Check Mode} and press
the [YES] key.
11) On the «System Operation Check Mode»
screen, select the {Actuator ON/OFF Operation}
and press the [YES] key.
12) On the «Actuator ON/OFF Operation» screen,
select the desired compulsory actuator and press
the [YES] key.
13) Pressing the [NO] key completes the compul-
sory valve operation check mode. The display will
then return to the «Actuator ON/OFF Operation»
screen.
ENGINE (DIAGNOSTICS)
EN-02097
(A)
EN-00040

Advertisement