Transmit | AUPC Page
Nominal Power
(dBm)
Min Power (dBm)
Max Power (dBm)
Target Eb/No (dB)
Web Browser
0 to -25 dB
0 to -45 dB
0 to -25 dB
0 to -45 dB
0 to -25 dB
0 to -45 dB
4.0 to 16 dB
7–26
DMD1050TS Satellite Modem Board
Use to set the nominal Transmit Power. The nominal
transmit power is the default output power level.
Use to set the minimum Transmit Power.
EBEM: When configured for EBEM AUPC, the minimum
Transmit Power is the lowest power setting that will be used
when the remote modem commands a decrease of the
Transmit Power from the Local modem.
EFDATA AUPC: When configured for EFDATA AUPC the
minimum Transmit Power is the lowest power setting that
will be used when the local modem commands a decrease
of the Transmit Power from the Remote modem.
RADYNE: When configured for Radyne AUPC, the
minimum Transmit Power is the lowest power setting that
will be used when the remote modem commands a
decrease of the Transmit Power from the Local modem.
NEARSIDE: When configured for NEARSIDE AUPC the
minimum Transmit Power is the lowest power setting that
will be used by the local modem when the Eb/No increases
above the Eb/No target.
Use to set the maximum Transmit Power.
EBEM: When configured for EBEM AUPC, the maximum
Transmit Power is the highest power setting that will be
used when the remote modem commands an increase of
the Transmit Power from the Local modem.
EF AUPC: When configured for EF AUPC, the maximum
Transmit Power is the highest power setting that the local
modem will use when the local modem commands an
increase in Transmit power from the Remote modem.
RADYNE: When configured for Radyne AUPC, the
maximum Transmit Power is the highest power setting that
will be used when the remote modem commands an
increase of the Transmit Power from the Local modem.
NEARSIDE: When configured for NEARSIDE AUPC the
maximum Transmit Power is the highest power setting that
will be used by the local modem when the Eb/No decreases
below the Eb/No target.
Use to set the desired Eb/No for the local receiver.
RADYNE AUPC: When configured for Radyne AUPC, this
setting is compared against the remote Eb/No and
commands to the local modem to increase or decrease the
local transmit power.
EF AUPC: When configured for EF AUPC, this setting is
compared against the local received Eb/No and commands
to the remote modem to increase or decrease transmit
power.
NEARSIDE: When configured for NEARSIDE AUPC, this
setting is compared against the received Eb/No of the local
modem and commands to the local modem to increase or
decrease transmit power.