1-2 Configuration of the BVP-900-series Camera System

1-2-10 S-BUS Control System Using the CNU-700

When a BKP-7933 S-BUS Interface Board is installed
in the CNU-700, the routing switcher system can
control the BVP-900-series camera system via the S-
BUS.
For details on installation and settings, refer to the
Installation Manual furnished with the BKP-7933.
CCU1
1
CCU2
2
CCU3
3
CCU4
4
CCU5
5
CCU6
6
BVP-900-series
CCU-700A/700AP/
video camera
550A/550AP
Switching the pictures sent to the picture monitors linked with RCP assignment
1-18
Chapter 1 Introduction
Source
number
Digital video routing switcher
SERIAL
(001)
OUT
IN1
SERIAL
(002)
IN2
OUT
SERIAL
(003)
IN3
OUT
SERIAL
(004)
IN4
OUT
SERIAL
(005)
IN5
OUT
SERIAL
(006)
IN6
OUT
CCU1
CCU2
CCU3
CCU4
CCU5
CCU6
CNU-700+BKP-7933
Switching the pictures sent to the picture
monitors linked with RCP assignment
When the MSU-700A/750 assigns an RCP, the camera
that is controlled with the assigned RCP-700-series
unit is changed, and the picture sent to each picture
monitor is also changed to the picture from the camera.
For example, the camera controlled with RCP-1 is
changed from CAM1 to CAM5, so the picture sent to
the picture monitor for RCP1 is changed from CAM1
to CAM5.
RCP1 RCP2 RCP3 RCP4 RCP5 RCP6
Destination
number
Picture monitors
RCP-700-series units
MSU1
MSU-700A/750

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bvp-900pBvp-950Bvp-950p

Table of Contents