1-2-4 Example When a BVP-950/950P Installed in a CA-905F/905K Is Used
CCD unit
Lens for studio use
CCD unit
Lens for studio use
TRIAX cable length
CCU-700A/700AP:
Diameter
Maximum
Maximum distance for
length
prompter signal transmission
8.5 mm
1000 m
500 m
14.5 mm
2000 m
1000 m
CCU-550A/550AP:
Diameter
Maximum
Maximum distance for
length
prompter signal transmission
8.5 mm
700 m
500 m
14.5 mm
1400 m
1000 m
BVP-950/950P
CA-905F/905K
BVP-950/950P
CA-570/570P
CA-905F/905K+BKP-9057
BVF-55/55CE
CA-570/570P
BVF-77/77CE/
7700/7700P
CCU-550A/550AP/
700A/700AP
Triax cable
Triax cable
1-7