To operate from the MSU-700A/750
Proceed as follows.
1
Press and light the CONFIG button of the menu
operation block.
The Configuration Menu appears on the display.
2
Press [CNU].
The CNU Configuration menu appears.
3
Press [RCP Assign].
The RCP Assignment menu appears.
Simultaneously, the character display of the CNU-
700 (see next page) changes to RCP Assignment
mode.
4
Using the four cursor move buttons on the RCP
Assignment menu (MSU-700A/750), move the
cursor on the character display of the CNU-700 to
the point to change the assignment.
Example
To change the assignment so that RCP5 controls
CCU1, set the cursor to the point where the CCU1
line crosses the RCP5 line.
Configuration Menu
MODE
Configuration Menu
Camera
CCU
MULTI
CNU
MSU
CARD
1
CONFIG
MAINTENANCE
FILE
PAINT
Example: MSU-700A
CNU Configuration menu
CNU Configuration
RCP
MSU
Assign
Assign
[MSU Assign] is displayed in Engineer mode only.
RCP Assignment menu
RCP Assignment
CCU1 – RCP1
Cursor move buttons
The cursor position on the character display of
the CNU-700 is indicated.
Chapter 4 Adjustments
2
Exit
Exit
Set
No
Assign
Default