Monitor - Sony BVP-900 Series System Manual

Video camera system
Hide thumbs Also See for BVP-900 Series:
Table of Contents

Advertisement

5
Adjust the signal level with the three left control
knobs.
Y: To adjust the black level of the Y signal sent
from the camera
R–Y: To adjust the black level of the R–Y signal
sent from the camera
B–Y: To adjust the black level of the B–Y signal
sent from the camera
6
Set the CB to ON on the VTR/CCU display of the
SYSTEM CONFIG menu of the camera and output
the color bar signals from the camrea.
For details on the color bar signal output, see Chapter
7 "Stand-Alone Operations of Cameras, etc."
7
Press [Level] to set it in inverse video to turn on
Level control mode.
The lower half of the display becomes the Level
control display.
SDI Output Level
Level
Black
Y
R-Y
0
0
8
Adjust the signal level with the control knobs as
shown below.
Adjusting on the CCU-700A/700AP
S2963
S2963 switch
AD board of the CCU-700A/700AP
1) Set the S2963 switch on the AD board to OFF.
2) Select the color-bar signals.
3) Select Y, R–Y, and B–Y on the SDI waveform

monitor.

B-Y
0
4) Turn the Y control so that the Y signal level
becomes 100%.
5) Turn the R–Y control so that the R–Y signal
level becomes 75%.
6) Turn the B–Y control so that the B–Y signal
level becomes 75%.
When the above adjustments are completed, set the
S2963 switch to ON.
Adjusting on the CCU-550A/550AP
1) Select the color-bar signals.
2) Select Y, R–Y, and B–Y on the SDI waveform
monitor.
3) Turn the Y control so that the Y signal level
becomes 100%.
4) Turn the R–Y control so that the R–Y signal
level becomes 75%.
5) Turn the B–Y control so that the B–Y signal
level becomes 75%.
To terminate the adjustment
Press the MAINTENANCE button to make it go dark.
3-79
Chapter 3 Initial Settings

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bvp-900pBvp-950Bvp-950p

Table of Contents