3-4.
SYSTEM CONTROL SYSTEM
ADJUSTMENTS

1. Battery down voltage adjustment

Purpose :
Sets the end voltage of battery discharge.
Adjustment Error : Usable period of a battery will be shortened,
or picture will be distorted at the battery end.
Mode
Camera record
Subject
Any subject
Measurement Point
LCD display of the adjustment
Measuring Instruments remote commander
Adjustment Page
F
Adjustment Address
26, 27, 28, 29, 2A
Note : Set the AUTO FOCUS to OFF (MANUAL).
Adjustment procedure:
Order
Page
Address
1
2
3
6
00
4
5
2
00
6
2
39
7
F
2A
8
9
F
26
27
28
29
10
2
00
11
6
00
12
Note 2 : Refer to the "Hexadecimal-Conversion Table" on page
6-12 , or 〈Conversion between the hexadecimal number
to decimal number〉 and 〈How to convert the decimal
number to hexadecimal number〉 on page 6-13 of the
Service Manual, conversion between decimal number s
and hexadecimal numbers.

2. Battery down voltage check

Connection :
Same connection as item "1. Battery down
voltage adjustment".
Order
1
Adjust the output voltage of the regulated power supply so that the digital voltmeter indicates 6.10 ± 0.01Vdc.
2
Insert a cassette and enter the camera recording mode. (CAM REC)
3
Adjust the output voltage of the regulated power supply so that the digital voltmeter indicates 5.53 ± 0.01Vdc.
Confirm that the battery down indication i on the TALLY LED and EVF flashes at the rate of 0.8Hz.
4
5
Adjust the output voltage of the regulated power supply so that the digital voltmeter indicates 5.25 ± 0.01Vdc.
Confirm that the battery down indication i on the TALLY LED and EVF flashes at the rate of 3.2Hz.
6
7
Press the START/STOP key. (CAM STBY)
Data
Adjust the output voltage of the regulated power supply so that the digital voltmeter
indicates 6.10 ± 0.01Vdc.
Insert a cassette and enter the camera recording mode. (CAM REC) After CAM REC is
stabilized (after elapse of about 5 seconds or more), proceed to the next step.
01
After setting the data and press the PAUSE button of the adjusting remote commander.
Adjust the output voltage of the regulated power supply so that the digital voltmeter
indicates 5.50 ± 0.01Vdc.
01
After setting the data and press the PAUSE button of the adjusting remote commander.
Read the data displayed on the adjustment remote commander. This data is named Dref.
After setting the data Dref and press thePAUSE button of the adjusting remote commander.
Convert Dref into the decimal number. The result decimal number is Dref '. (Note 2)
Calculate the following equation (decimal calculation) to obtain the following adjustment
data (decimal number). Convert the adjustment data into hexadecimal numbers
respectively, and set the hexadecimal data into the respective adjustment addresses.
(Note 2) After setting the data, be sure to press the PAUSE button of the adjusting remote
commander.
Address : 0F
D
0F
Address : 0E
D
0E
Address : 0D
D
0D
Address : 0C
D
0C
00
After setting the data and press the PAUSE button of the adjusting remote commander.
00
After setting the data and press the PAUSE button of the adjusting remote commander.
Turn off the main power.
Procedure
' = Dref '+ 16
' = Dref '+ 13
' = Dref '+ 10
' = Dref '+ 5
Procedure
6-48