Checking And Adjusting The Signal Of The System; Resetting The Control Data - Sony BVP-900 Series System Manual

Video camera system
Hide thumbs Also See for BVP-900 Series:
Table of Contents

Advertisement

3-3 Checking and Adjusting the Signal of the System

The signal levels of the units used in the BVP-900-
series camera system are set to the standard values at
the factory. Before starting operation, check the levels
of the units, and adjust them if necessary. Basically,
adjustment is performed with the controls and switches
on the internal boards, but some adjustment can be
made from the Maintenance Menu of the MSU-700A/
750. For such items, perform basic adjustment with
the switches and controls on the boards, and fine
adjustment with the Maintenance Menu.
If level difference between the units is extreme, adjust
the levels referring to the maintenance manuals.
Adjustment after "3-3-2 Adjusting the Phases of the
Signals" should be performed with the power on.
After resetting the control data as shown in
"3-3-1 Resetting the Control Data" below turn the
power of all the units on.
For details on power supply, see "4-2-1 Power Supply."

3-3-1 Resetting the Control Data

Before adjustment, reset the control data of the CCU-
700A/700AP/550A/550AP, VCS-700, and BVP-900/
900P/950/950P.
Resetting the control data of the
CCU-700A/700AP
Proceed as follows.
S1001
S1001 switch
MODE 1
S1002 switch
MODE 2
S1002
AT board of the CCU-700A/700AP
1
Set all switches of the S1001 switch and switches 1
through 7 of the S1002 switch on the AT board to
OFF.
2
Set switch 8 of the S1002 switch to ON.
3
Turn the power of the CCU-700A/700AP ON.
4
Turn the power of the CCU-700A/700AP OFF.
The control data are then reset.
5
Set all switches of the S1001 and S1002 switches
to OFF or to their previous settings.
All switches of the S1001 and S1002 switches are set
to OFF at the factory.