1-2 Configuration of the BVP-900-series Camera System
Camera control unit that can be connected
The CCU-550A/550AP and CCU-700A/700AP can be
connected under the following limitations:
• When the BKP-5974 DC power unit has been
installed in the CCU-550A/550AP, the CA-905F/
905K cannot be used.
• When you connect the BVF-7700/7700P to the unit,
the CCU-550A/500AP cannot be used. Use the
CCU-700A/700AP.
• When the CA-570/570P is connected to the CCU-
550A/550AP, only one channel can be used for
intercom transmission. Use the INCOM1 connector
on the CA-570/570P.
Note
The CCU-550/550P cannot be used with the CA-905F/
905K.
Setting of the intercom microphone switch
When you use the intercom microphone switch located
on the zoom demand of the studio zoom lens, be sure
to set the intercom microphone switch of the CA-570/
570P to OFF (center position).
Check of ROM Version
When connecting the camera, be sure to check the
version of ROM on the AT-121 board corresponding
to the camera to be connected.
If ROM version differ from the below table, be sure to
perform ROM replacement.
Ref. No.
ROM version
IC8
Ver.1.22 or higher
IC9
Ver.1.22 or higher