Adjusting The Master Black; Adjustments - Sony BVP-900 Series System Manual

Video camera system
Hide thumbs Also See for BVP-900 Series:
Table of Contents

Advertisement

4-4-4 Adjusting the Master Black

Adjust the master black level.
When using the RCP-720/721/730/731/740, you can
select the adjustment mode with the RELATIVE
button.
Example: RCP-721
RELATIVE
MASTER BLACK
Relative mode (RELATIVE button lit): There is no
absolute correspondence between the position of
the ring (or knob) and the adjustment value. The
position of the ring when Relative mode is selected
will be the reference position for the subsequent
adjustment. The center position does not always
represent the median value for the adjustment.
In the following cases, Relative mode is
automatically selected.
– When an auto setup operation is completed
– When a scene file is retrieved
– When the IRIS/MB ACTIVE button goes
dark
Absolute mode (RELATIVE button not lit): The
position of the ring (or knob) absolutely
corresponds to the adjustment value and the center
position always represents the median value of the
adjustment.
Note
Adjusting on the MSU-700A/750 and RCP-700/701/
741 is always performed in Relative mode.
To adjust from the MSU-700A/750
Use the MASTER BLACK control.
MASTER BLACK
MASTER
BLACK control
The MSU-700A/750 also permits you to adjust the
master black on the black adjustment display of Paint
menu.
See "4-4-3 Adjusting the Black Balance."
RELATIVE button
MASTER BLACK
control knob
Display window:
The setting (–99 to 99)
is displayed.
Example: MSU-700A
To adjust from the RCP-700/720/730/740
Use the MASTER BLACK control ring.
On the RCP-740, the corresponding LED of the
MASTER BLACK indicator lights according to the
master black setting.
On the RCP-720, the set value (–99 to 99) appears in
the display window.
RELATIVE button
RELATIVE
RELATIVE
IRIS/MB
ACTIVE
ALARM
CLOSE
CALL
AUTO
MASTER
PANEL
ACTIVE
BLACK
MASTER BLACK indicator
To adjust from the RCP-701/721/731/741
Use the MASTER BLACK control.
On the RCP-741, the corresponding LED of the
indicator around the control lights according to the
master black setting.
On the RCP-721/731, the set value (–99 to 99) appears
in the display window.
MASTER
BLACK control
MASTER BLACK
PANEL
ACTIVE
Example: RCP-741
Automatic adjustment of the master black
On the MSU-700A/750 or the RCP-720/721/730/731/
740/741, the master black can also be automatically
adjusted along with other items with an auto setup
operation.
For details, see "4-19 Auto Setup."
Master black control ring
EXT
SENS
1.4
2.0
2.8
CLOSE
OPEN
4.0
COARSE
5.6
8.0
11
0
15
22
CLOSE
IRIS
Example: RCP-740
ALARM
CALL
PREVIEW
4-39