3-3 Checking and Adjusting the Signal of the System
3-3-2 Adjusting the Phases of the
Signals
The signal phases between the units used in the BVP-
900-series video camera system must be adjusted so
that the phases are aligned. Before starting adjustment,
supply the following reference signals to each piece of
equipment, and turn the power of each unit ON.
CCU-700A/700AP/550A/550AP
A signal including a burst and sync signals
Signal level: 40 IRE (for CCU-700A/550) or 0.3 Vp-p
(for CCU-700AP/550P)
CNU-700/500
A signal including a sync signal
Signal level: 40 IRE (for the NTSC model) or 0.3 Vp-p
(for the PAL model)
Waveform monitor
A sync signal specified by the waveform monitor to be
used
Adjusting the phases of the sync signal of
the CCU-700A/700AP/550A/550AP
Adjust the phases of the output signals of all the CCU
used in the system so that the phases of the output
signals align the phase of the reference signal. You
can adjust the phase using the controls and switches on
the VA board of the CCU-700A/700AP/550A/550AP
and also with the Maintenance Menu of the MSU-
700A/750.
Adjusting on the VA board of the CCU-700A/700AP
Proceed as follows.
VA
BC PHASE H PHASE
V
–12 –5 +5 +12
BLANNKING
REMOTE LOCAL
FINE COARSE FINE
19 20 21
STEP
H
H PHASE FINE control
H PHASE COARSE control
SC PHASE FINE control
SC PHASE STEP switch
REMOTE/LOCAL switch
VA board of the CCU-700A/700AP
1
Set the REMOTE/LOCAL switch on the VA board
to LOCAL.
2
Roughly adjust the SC phase with the SC PHASE
STEP switch.
3-66
Chapter 3 Initial Settings
BLACK
STAIR
WFM1
BALANCE
STEP
BURST
VBS
GEN
LEVEL
LEVEL
LEVEL
PHASE
I
O CHROMA Y
LOCK
POSITION
3
Perform fine adjustment of the SC phase with the
SC PHASE FINE control.
4
Roughly adjust the H phase with the H PHASE
COARSE control.
5
Perform fine adjustment of the H phase and SC-H
phase with the H PHASE FINE control.
Repeat steps 2 through 5 on all the CCU-700A/
700APs in the system.
Adjusting on the VA board of the CCU-550A/
550AP
Proceed as follows.
VA
STEP
WFM
ALARM
0° 180°
FINE
H PHSE
LEVEL
REM
LOCAL
SC PHASE
VA board of the CCU-550A/550AP
1
Set the REMOTE/LOCAL switch on the VA board
to LOCAL.
2
Roughly adjust the SC phase with the SC PHASE
STEP switch.
3
Perform fine adjustment of the SC phase with the
SC PHASE FINE control.
4
Adjust the H phase and SC-H phase with the H
PHASE control.
Repeat steps 2 through 4 on all the CCU-550A/
550APs in the system.
STAIR
BLACK
BURST
VBS
STEP
BALANCE
LEVEL
LEVEL PHASE Q/U
I/V CHROMA Y
POSITION
H PHASE control
SC PHASE FINE control
SC PHASE STEP switch
REMOTE/LOCAL switch