Omron NX701-17 Series User Manual page 217

Nj/nx-series, machine automation controller, cpu unit built-in ethercat port
Hide thumbs Also See for NX701-17 Series:
Table of Contents

Advertisement

Event name
EtherCAT Diagnosis/Statistics Log Ended
Meaning
EtherCAT diagnosis/statistics log is ended.
Source
EtherCAT Master Function Module
Error attributes
Level
Effects
User program
Indicators
EtherCAT NET RUN
---
System-defined
Variable
variables
_EC_StatisticsLogEnable
_EC_StatisticsLogBusy
_EC_StatisticsLogErr
Cause and
Assumed cause
correction
An error that causes EtherCAT diag-
nosis/statistics log to end occurred.
Attached
Attached information 1: Automatic saving interval to the SD Memory Card for the diagnosis/statistics log
information
0: One-shot Mode
Not 0: Interval (sec)
Attached information 2: Causes to end EtherCAT diagnosis/statistics log
1: The value of the _EC_StatisticsLogEnable changed from TRUE to FALSE.
2: The 1000th record was saved in the log file.
3: The SD Memory Card does not have sufficient available space to save another records in the log file.
4: The SD Memory Card is write protected.
5: The SD Memory Card cannot be recognized.
6: Synchronizing (or downloading)
7: An invalid value was specified to the automatic saving interval to the SD Memory Card for the diagnosis/statis-
tics log.
Precautions/
None
Remarks
*1 This event code occurs for unit version 1.11 or later of the CPU Unit.
NJ/NX-series CPU Unit Built-in EtherCAT Port User's Manual (W505)
Source details
Information
Recovery
Continues.
Operation
EtherCAT NET ERR
---
Data type
BOOL
BOOL
BOOL
Correction
---
9 Troubleshooting
Event code
94510000 hex
Master
Detection
timing
---
Log category
Not affected.
EtherCAT LINK/ACT
---
Name
Diagnosis/Statistics Log Enable
Diagnosis/Statistics Log Busy
Diagnosis/Statistics Log Error
Prevention
---
*1
When EtherCAT
diagnosis/statis-
tics log is ended
Access
9
9-47

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents