Event code
Event name
34400000 hex
Network
Configura-
tion Informa-
tion Error
34410000 hex
EtherCAT
(Ver. 1.10 or
Communica-
later)
tions Cycle
Exceeded
50010000 hex
Controller
(Ver. 1.02 or
Insufficient
later)
Memory
Warning
84210000 hex
Network
Configura-
tion Error
84220000 hex
Network
Configura-
tion Verifica-
tion Error
NJ/NX-series CPU Unit Built-in EtherCAT Port User's Manual (W505)
Meaning
Assumed cause
There is an error in
• The power supply to the Con-
the network config-
troller was interrupted or com-
uration information.
munications with the Sysmac
Studio were disconnected while
downloading the network con-
figuration information.
Process data com-
• The transmission delay time in
munications could
the actually connected configu-
not be performed
ration is longer than the trans-
with the specified
mission delay time calculated
communications
for the user-set cable length.
cycle.
• The set task period or commu-
nications cycle is too short.
The amount of data
• The amount of data for the Eth-
for the EtherCAT
erCAT slave configuration, net-
slave configura-
work-published information, or
tion, network-pub-
other data exceeds the value
lished information,
that is specified for the CPU
or other data
Unit.
exceeds the value
that is specified for
the CPU Unit. You
may not be able to
perform online edit-
ing or other opera-
tions.
The EtherCAT net-
• Slave output ports are con-
work configuration
nected to each other.
is incorrect.
• The master and slave are con-
nected with the slave output
port.
• The number of connected
slaves exceeded the maximum
number of slaves for the Ether-
CAT master.
A slave that is in the
• A slave that is in the network
network configura-
configuration information is not
tion information is
connected.
not connected. Or,
• There is a node address mis-
a slave that is not in
match.
the network config-
• A different slave from the one
uration information
that is specified in the network
is connected.
configuration information is
connected.
• A slave that is not in the net-
work configuration information
is connected.
• The hardware switches for the
slave node address were
changed to a value other than 0
after the Write Slave Node
Address operation was per-
formed from the Sysmac Stu-
dio.
• The Ethernet physical layer is
broken between two slaves.
9 Troubleshooting
Level
Maj
Prt
Min
Obs Info
page 9-23
page 9-24
page 9-24
page 9-25
page 9-27
Reference
9
9-11