Table 2-16. RTRV-CRAFT Output Fields (Continued)
Field
priority
The provisioned priority level for the PRS input.
1 | 2 | 3 | 4
frmtype
The PRS input frequency setting.
2M | 5M | 10M
inpstatus
The current status of the specified input.
OK | ALM
instate
The state of the specified input.
ENABLE | DISABLE | MONITOR
qlevel
The provisioned quality level for the specified input.
1 | 2 | ... | 9
priority
The provisioned priority level for the specified input.
1 | 2 | 3 | 4
frmtype
The frame signal type provisioned for the specified input.
2M | CCS | D4 ESF | CC
rqlevel
The quality level received on the specified input.
1 | 2 | ... | 10
crcena
The specified input is provisioned to utilize CRC4 checking.
ENABLE | DISABLE
ssmena
The specified input is provisioned to read the received SSM.
ENABLE | DISABLE
ssmbit
The bit position at which the specified input is provisioned to read SSM.
4 | 5 | 6 | 7 | 8
outstatus
The current status of the specified output group.
OK | ALM | UNEQUIPPED
outstate
The state of the specified output group.
ENABLE | DISABLE
frmtype
The framing type that the specified output group is provisioned to generate.
2M | CAS | D4 | ESF | CC | ISOLATED_1
freeflt
The type of signal to be generated on the specified output group when the Local
Oscillator enters Free-run mode.
ON | SQUELCH AIS
holdflt
The type of signal to be generated on the specified output group when the Local
Oscillator enters Holdover mode.
ON | SQUELCH AIS