Symmetricom TimeProvider 1100 Reference Manual page 163

Edge clock tl1 reference guide
Hide thumbs Also See for TimeProvider 1100:
Table of Contents

Advertisement

Table C-1. Event Identifiers (Continued)
Event ID
or
Event Description
CONDTYPE
INSTATE
The state of the input
ports used by the system
PMCLR
Allows the user to Clear
the gathered
Performance Data that is
stored in the IMC
module.
PRIORITY
Allows the user to
provision the priority of
the input using
RQLEVEL
The Received Quality
Level represents the
received SSM on INP1 or
INP2, this allows
notification of changing
SSMs
QLEVEL
Allows the user to
provision the Quality
Level of the input.
SSMBIT
Allows the user to
provision E1 (CAS/CCS)
SSM bit position to allow
the input to determine to
proper bit to read the
SSM on.
097-58001-01 Revision E – September 2006
AID
Default Value
TYPE
T1
ENABLE
EQPT NA
T1
1 (GPS)
1 (PRS)
2 (INP1)
3 (INP2)
T1
2
T1
2
T1
8
Appendix C Events
Value Description
DISABLE – Disabled inputs,
associated active alarms are
cleared.
ENABLE – Enabled inputs, are
available as system reference.
MONITOR – Allows the input
to be monitored for
performance and signal faults,
but cannot be selected as
reference input.
NA
1 = Highest
2
3
4 = Lowest
1 = PRC/PRS
2 = UNK/STU
3 = TYPE II/ST2
4 = TYPE I
5 = TYPE V/TNC
6 = TYPE III/ST3E
7 = TYPE IV/ST3
8 = 811OPT3/SMC
9 = DUS
1 = PRC/PRS
2 = UNK/STU
3 = TYPE II/ST2
4 = TYPE I
5 = TYPE V/TNC
6 = TYPE III/ST3E
7 = TYPE IV/ST3
8 = 811OPT3/SMC
9 = DUS
4 | 5 | 6 | 7 | 8
TimeProvider TL1 Reference Guide 163

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Timeprovider 1000

Table of Contents