Chapter 2 TL1 Command Syntax and Description
Edit Sync (ED-SYNC)
Table 2-6. ED-SYNC – Keywords and Values (Continued)
<keyword>
<value>
FRMTYPE
1.544M
2M
5M
6.312M
10M
Note: If the input frequency does not match the FRMTYPE setting,
an input loss-of-signal (INPLOS) condition results.
QLEVEL
PRIORITY
FRMTYPE
2M
Note: When the
CAS
TimeProvider is in
Subtending mode,
CCS
see
"Set System
D4
Mode
(SET-SYS-MODE
ESF
)"
on page 134,
the frame signal
type is
1.544M
automatically set
to Composite
6.312M
Clock (CC or JCC)
CC
by the system.
The Composite
JCC
Clock FRMTYPE
cannot otherwise
be selected by the
JCC4
user.
CRCENA
ENABLE
DISABLE
Note: If an input is provisioned to read SSMs (SSMENA=ENABLE),
CRC4 must be provisioned first.
58
TimeProvider TL1 Reference Guide
The PRS input frequency is provisioned as
1.544 MHz.
The PRS input frequency is provisioned as 2 MHz
(2048 kHz).
The PRS input frequency is provisioned as 5 MHz.
The PRS input frequency is provisioned as
6.312 MHz.
The PRS input frequency is provisioned as 10 MHz.
<aid> = INPp
Refer to the QLEVEL description under the <aid> =
GPS heading in this table.
Refer to the PRIORITY description under the <aid> =
GPS heading in this table.
Specified input frame signal type is 2M.
Specified input frame signal type is CAS.
Specified input frame signal type is CCS.
Specified input frame signal type is D4 (Super Frame).
Specified input frame signal type is ESF (Extended
Super Frame).
1
Specified input frame signal type is 1.544 MHz.
Specified input frame signal type is 6.312 MHz.
1
Specified input frame signal type is Composite Clock.
1
Specified input frame signal type is Japanese
Composite Clock.
1
Specified input frame signal type is Japanese
Composite Clock 400 Hz.
Enables the use of CRC4 checking on the input.
Disables the use of CRC4 checking on the input.
Description
097-58001-01 Revision E – September 2006
Default
2M
2M
ESF
DISABLE