Symmetricom TimeProvider 1100 Reference Manual page 148

Edge clock tl1 reference guide
Hide thumbs Also See for TimeProvider 1100:
Table of Contents

Advertisement

Appendix B Alarms
Table B-1. Alarms (Continued)
Alarm ID
Alarm Condition
or
Description
CONDTYPE
INPDISQ
The specified input was
Disqualified or Qualified
as a possible system
reference. The fault
condition must be
continuously present for
the Fault Delay Time
(FLTDELAY) before
disqualifying the input
as a possible reference.
After INPDISQ is set,
the alarm clears when
the input signal is fault
free for the Clear Delay
Time (CLRDELAY).
INPLOS
The specified input port
has Loss Of Signal.
When LOS is detected,
the input is immediately
removed from the
possible reference list.
The LOS must be
continuously present for
the Fault Delay Time
(FLTDELAY) before
disqualifying the input
as a possible reference.
After INPLOS is set, the
alarm clears when the
input signal is LOS free
for the Clear Delay Time
(CLRDELAY).
148 TimeProvider TL1 Reference Guide
Error
AID
Service
Delay
Type
Affecting
Default
<aid> = PRS
T1
NSA
FLT
DELAY
T1
NSA
IMMED
Alarm Default
Error
Level
Delay
Editable
SSU PRS SUB
YES
MN
MN
NO
MN
MN
097-58001-01 Revision E – September 2006
MN
MN

Hide quick links: