Appendix C Events
Table C-1. Event Identifiers (Continued)
Event ID
or
Event Description
CONDTYPE
XFEROK
The transfer of IMC Istate
to the IOC was
successful. The transfer
of IOC Istate to the IMC
was successful. The
transfer of IOC Istate to
the redundant IOC was
successful.
CKTIDCHG A user has modified the
Circuit ID for the GPS
input.
MODE
User set/request for
system position when
using GPS or when
position is automatically
found
POS
User set/request for GPS
Antenna Latitude,
Longitude, Height
ELEVMASK User set/request for GPS
Elevation Mask
RESET
GPS power has been
reset.
CCALIGN
Allows the user to clear
the INPTRR alarm or
clear INPTRR and force
alignment between the
CC output and a CC
input.
CLKTYPE
The specified IOC sets
the clock type to the
specified value. The
value is used to define
module pull in range and
SSM generation during
Holdover.
160 TimeProvider TL1 Reference Guide
AID
Default Value
TYPE
EQPT NA
GPS Event Codes
T1
GPS
EQPT AUTO
EQPT dd-mm-ss.ss(N
or S)
dd-mm-ss.ss(E
or W)
+/-hhhh.h
EQPT dd
EQPT NA
IOC Event Codes
T1
NA
EQPT TYPEI
Value Description
NA
The ID can be up to 40 characters
in length.
AUTO | MANUAL
dd-mm-ss.ss(N|S).
dd-mm-ss.ss(E|W),+/-hhhh.hh
5 to 45 (default is 10) degrees
NA
NA
ST3E | TYPEI | ST2 |TYPEII
097-58001-01 Revision E – September 2006