Symmetricom TimeProvider 1100 Reference Manual page 49

Edge clock tl1 reference guide
Hide thumbs Also See for TimeProvider 1100:
Table of Contents

Advertisement

Table 2-5. ED-EQPT – Keywords and Values (Continued)
<keyword>
<value>
INSTATE
ENABLE
DISABLE
MONITOR The specified input is in monitor-only mode.
INSTATE
ENABLE
DISABLE
MONITOR The specified input is in monitor-only mode.
OUTSTATE
ENABLE
DISABLE
OUTSTATE
ENABLE
DISABLE
RTMSTATE
ENABLE
DISABLE
SLIPCLR
NA
Note: See
parameters.
097-58001-01 Revision E – September 2006
Description
<aid> = PRS
The specified input is enabled.
The specified input is disabled.
Note: In monitor-only mode, the input is monitored for
signal faults and the performance of the input is
monitored, but the input cannot be selected as a system
reference or used as a BesTime backup reference.
<aid> = INPp
The specified input is enabled.
The specified input is disabled.
Note: In monitor-only mode, the input is monitored for
signal faults and the performance of the input is
monitored, but the input cannot be selected as a system
reference or used as a BesTime backup reference.
<aid> = OUTg
The specified output group is enabled.
The specified output group is disabled.
<aid> = E422g
The specified EIA-422 output group is enabled.
The specified EIA-422 output group is disabled.
<aid> = RTMg[-p]
The specified Retimer group is enabled.
The specified Retimer output group is disabled.
Clears a current Slip alarm from the specified port.
Edit Sync
(ED-SYNC), on page 55 for more provisioning
Chapter 2 TL1 Command Syntax and Description
Edit Equipment (ED-EQPT)
TimeProvider TL1 Reference Guide
Default
DISABLE
ENABLE
DISABLE
DISABLE
ENABLE
NA
49